Quick tech specs
- 10kOhms Primary Impedance
- Matches High-to-Low Impedance or Low-to-High Impedance
- RCA Connector for Hi-Z Side
- Small Steel Enclosure with Mounting Ears Allows Easy Mounting
- 600Ohms Secondary Impedance
- Adapts Line Level Signals to Microphone Inputs
- Screw Terminals for Lo-Z Side
Know your gear
The Bogen Line Matching Transformer is designed specially for impedance-matching inputs from, or outputs to, a 600- Ohm line. It has a Hi-Z, 10k-Ohm primary impedance and a Lo-Z, 600-Ohm secondary impedance balanced with a center tap. As an input-matching transformer, it can be used to connect telephone systems to most Bogen public address amplifiers for telephone paging. It can also adapt speaker-level signals (25/70-volt systems) to a level suitable for the AUX input of an amplifier.